Sign in →

Platelet Function Analysis

Icon & Photos

Blue Top (Citrate Tube)

 Lavender top (EDTA Tube)

Specimen Requirements

Preferred:
Container/Tube: Blue Top (Citrate Tube) and Lavender top (EDTA Tube)
Minimum Volume: 2 Full (2.7 mL) Blue top and Full (4.0 mL) EDTA

Specimen Stability

Ambient:4 hours
DO NOT REFRIGERATE

Reference Range

COL/EPI 71 – 92 sec
COL/ADP 55 – 115 sec

Methodology

The PFA-100® is an instrument and test cartridge system in which the process of platelet adhesion and aggregation is simulated in vitro mimicking injured endothelium. The time necessary to block a membrane coated with collagen and epinephrine or collagen and ADP is measured and called closure time.

CPT

85576 (x2)

Lab Handling

Specimen should NOT be placed on a rocker or rotator while awaiting testing