Sign in →

Culture Body Fluid

Icon & Photos

Sterile Tube or Syringe

Specimen Requirements

Preferred:
Container/Tube: 10 mL Fluid in a Sterile Tube or Syringe
Minimum Volume: 0.5 mL
Collection Instructions: Skin decontamination with providone iodine. Use asceptic aspiration with a syringe and needle, place immediately into tubes provided by the lab (for Synovial or Serous fluid collection lab kits)

Specimen Stability

Ambient: Transport to the lab as soon as possible
Refrigerate: 2 Weeks

Reference Range

No Growth

Methodology

Manual

CPT

87071

Lab Handling

Fluid Culture Procedure.