Sign in →

Echovirus Antibodies

Important Note

Cerner Order Name:   Send-out Other

ARUP Test code: 0060053

Icon & Photos

Gold Top (SST-Gel)

Specimen Requirements

Preferred:
Container/Tube: Gold Top (SST-Gel)
Minimum Volume: 1.0 mL
Collection Instructions: Centrifuge within 2 hours
Also Acceptable:
Container/Tube: Plain Red Top Tube

Unacceptable

CSF or plasma. Contaminated, hemolyzed, or severely lipemic specimens.

Specimen Stability

Ambient: 48 hours
Refrigerate: 2 weeks
Frozen: 1 year

Reference Range

Echovirus 6:  Less than 1:10
Echovirus 7:  Less than 1:10
Echovirus 9:  Less than 1:10
Echovirus 11: Less than 1:10
Echovirus 30: Less than 1:10

Methodology

Semi-Quantitative Serum Neutralization

CPT

86658 x5

Turn Around Time

Performed

Mon-Fri

Reported

6-9 days

Lab Handling

Separate from cells ASAP or within 2 hours of collection. Transfer 1 mL serum to an ARUP Standard Transport Tube. (Min: 0.3 mL) Parallel testing is preferred and convalescent samples must be received within 30 days from receipt of acute samples.

Storage and Transport Temperature

Refrigerated.

Test Alias

  • Echovirus Ab Panel
  • Echovirus Antibodies
  • Echovirus antibody profile, IgG, IgM
  • Echovirus Antibody, Neutralization
  • Enterovirus