Legionella pneumophila Antibody (Types 1-6) IgM by IFA
Icon & Photos
Gold Top (SST-Gel)
Specimen Requirements
Preferred:
Container/Tube: Gold Top (SST-Gel)
Minimum Volume: 1.0 mL
Collection Instructions: Centrifuge within 2 hours
Unacceptable
Contaminated, heat-inactivated, hemolyzed, or severely lipemic specimens
Specimen Stability
Ambient: 48 hours
Refrigerate: 2 weeks
Frozen: 1 year
Reference Range
< 1:16
Methodology
Semi-Quantitative Indirect Fluorescent Antibody
CPT
86713
Lab Handling
Separate serum from cell ASAP or within 2 hours of collection. Transfer 1 mL serum to an ARUP Standard Transport Tube. (Min: 0.1 mL) Parallel testing is preferred and convalescent specimens must be received within 30 days from receipt of the acute specimens. Mark specimens plainly as acute or convalescent.
Storage and Transport Temperature
Refrigerated.
Turn Around Time
Performed
Mon-Fri
Reported
1-4 days
Test Alias
- L pneumophila IgM
- L pneumophila Types 1-6 Ab
- Legionella pneumophila IgM antibody
- Legionnaires Disease Testing