Sign in →

Volatile Alcohol Panel

Important Note

Cerner Order Name: Sendout: Other

OSU Test Code: INPT366

Call OSU Wexner 614-293-8375 to let them know of STAT Lab

 

 

Clinical Information

This test is intended to measure the concentration of acetone, ethanol, isopropanol, and methanol in serum or plasma samples.

Profile Information

Reporting Name Available Separately Always Reported
Methanol, Blood No Yes
Ethyl Alcohol, Blood No Yes
Acetone, Blood No Yes
Isopropanol, Blood No Yes

Icon & Photos

Gold Top (SST-Gel)

Specimen Requirements

Use a non-alcohol based cleanser to clean the collection site

Preferred Container/Tube: Gold SST Top
Acceptable Container/Tube: Gold SST Top, Red Top, Mint Green Top
Specimen Volume: 1 mL
Specimen Minimum Volume: 0.5 mL

Specimen Stability

Ambient: 24 hours
Refrigerated: 7 days

Reference Range

METHANOL
<10 mg/dL

ETHYL ALCOHOL
<10 mg/dL

ACETONE
<10 mg/dL

ISOPROPANOL
<10 mg/dL

Methodology

Gas Chromatography (GC) Flame Ionization Detection (FID)

CPT

G0480

Day(s) Performed

Monday through Sunday

Volatile Panel is not run after 23:00

 

Report Available

Same day/1 day

Synonym

  • VOLABU
  • Alcohol
  • Drug
  • Methanol
  • Ethanol
  • Isopropanol
  • Acetone
  • Ethyl Alcohol
  • Isopropyl Alcohol

Test Classification

This Gas Chromatography (GC) test was developed and its performance characteristics determined by the Toxicology Laboratory at The Ohio State University Wexner Medical Center, it has not been cleared or approved by the FDA. The laboratory is regulated under CLIA as qualified to perform high complexity testing. This test is used for clinical purposes and should not be regarded as investigational or for research.