Sign in →

Mycoplasma genitalium, RNA

Important Note

This test is not intended for use on patients under age 14

Icon & Photos

Aptima Unisex Swab

Aptima Multitest Swab

 

Aptima Urine Collection

 

Random Urine Container

 

 

 

 

Specimen Requirements

Submit only 1 of the following specimens:

 

Specimen Type: Endocervix/Cervix

Supplies: Aptima Unisex Swab Collection Kit (T583)

Container/Tube: Aptima Unisex Swab

Specimen Volume: 1 Swab

Collection Instructions:

1. Specimens must be collected using the Aptima Unisex Swab Collection Kit.

2. Use cleaning swab (white shaft) to remove excess mucus from endocervix/cervix.

Discard the cleaning swab.

3. Insert second swab (blue shaft) 1 to 1.5 cm into endocervical canal, and rotate swab gently for 30 seconds. Avoid touching vaginal wall when removing swab.

4. Place blue swab into Aptima transport tube provided in collection kit.

5. Snap off blue swab at score line so it fits into closed tube.

7. Cap tube securely and label tube with patient's entire name and collection date and time.

8. Maintain swab container at 2 to 30° C (refrigerate temperature is preferred), transport within 60 days of collection.

 

Specimen Type: Vaginal

Supplies: Aptima Multitest Swab Collection Kit (T584)

Container/Tube: Aptima Multitest Swab

Specimen Volume: 1 Swab

Collection Instructions:

1. Specimens must be collected using the Aptima Multitest Swab Collection Kit.

2. Insert swab (pink shaft) about 5 cm past introitus and rotate gently for 30 seconds.

3. Place pink swab into Aptima transport tube provided in collection kit.

4. Snap off pink swab at score line so it fits into closed tube.

5. Cap tube securely and label tube with patient's entire name and collection date and time.

6. Maintain swab container at 2 to 30° C (refrigerate temperature is preferred), transport within 60 days of collection.

 

Specimen Type: Urethra (Male patients only)

Supplies: Aptima Unisex Swab Collection Kit (T583)

Container/Tube: Aptima Unisex Swab

Specimen Volume: 1 Swab

Collection Instructions:

1. Specimens must be collected using the Aptima Unisex Swab Collection Kit.

2. Patient should not have urinated for at least 1 hour prior to collection.

3. With a rotating movement, insert swab (blue shaft) 2 to 4 cm into urethra.

4. Once inserted, rotate swab gently at least 1 full rotation using sufficient pressure to ensure swab comes in contact with all urethral surfaces. Allow swab to remain inserted for 2 to 3 seconds.

5. Place blue swab in transport tube provided in collection kit.

6. Snap off blue swab at score line so it fits into closed tube.

7. Cap tube securely, and label tube with patient's entire name and collection date and time.

8. Maintain swab container at 2 to 30° C (refrigerate is preferred temperature) within 60 days of collection. If longer storage is needed, freeze at -20 to -70° C for an additional 90 days.

 

Specimen Type: Urine

Supplies: Aptima Urine Transport Tube (T582)

Container/Tube: Aptima urine specimen transport tube

Specimen Volume: 15 to 20 mL

Collection Instructions:

1. Patient should not have urinated for at least 1 hour prior to specimen collection.

2. Patient should collect first portion of random voided urine (first part of stream) into a sterile, plastic, preservative-free container.

3. Within 24 hours of collection, transfer 2 mL of urine into the Aptima urine specimen transport tube using the disposable pipette provided. The correct volume of urine has been added when the fluid level is between the black fill lines on the Aptima urine transport tube.

4. Maintain Aptima urine specimen transport tube at 2 to 30° C (refrigerate temperature is preferred), transport within 30 days of collection.

Specimen Type: Penile/meatal

Supplies: Aptima Multitest Swab Collection Kit (T584)

Container/Tube: Aptima Multitest Swab

Specimen Volume: 1 Swab

Collection Instructions:

1. Specimens must be collected using the Aptima Multitest Swab Collection Kit.

2. Roll the swab (pink shaft) just at the tip or outside the opening to the penis. Be sure to roll the swab completely around the opening to get the best sample.

3. Immediately place the pink swab into the collection tube.

4. Carefully break the pink swab shaft at the score line and recap the tube.

5. Cap tube securely and label tube with patient's entire name and collection date and time.

6. Maintain swab container at 2 to 30° C (refrigerate is preferred temperature) within 60 days of collection. If longer storage is needed, freeze at -20 to -70° C for an additional 90 days.

 

 

 

Specimen Stability

Specimen Type Temperature Time Special Container
varies Refrigerated (preferred) 30 days       APTIMA VIAL
  Frozen  60 days APTIMA VIAL
  Ambient  30 days APTIMA VIAL

Reference Range

Negative

CPT

87563

 

Day(s) Performed

Tuesday and Thursday

Report Available

24-72 hours

Reject Due To

Midstream urine specimen
Clean catch urine specimen
Over-filled or under-filled urine transport tubes
Specimen collected into a SurePath device
Transport tubes containing a cleaning swab or more than 1 swab
Multiple sources on single tube