Mycoplasma genitalium, RNA
Icon & Photos
|
Aptima Unisex Swab Aptima Multitest Swab
Aptima Urine Collection
Random Urine Container
|
Specimen Requirements
Submit only 1 of the following specimens:
Specimen Type: Endocervix/Cervix
Supplies: Aptima Unisex Swab Collection Kit (T583)
Container/Tube: Aptima Unisex Swab
Specimen Volume: 1 Swab
Collection Instructions:
1. Specimens must be collected using the Aptima Unisex Swab Collection Kit.
2. Use cleaning swab (white shaft) to remove excess mucus from endocervix/cervix.
Discard the cleaning swab.
3. Insert second swab (blue shaft) 1 to 1.5 cm into endocervical canal, and rotate swab gently for 30 seconds. Avoid touching vaginal wall when removing swab.
4. Place blue swab into Aptima transport tube provided in collection kit.
5. Snap off blue swab at score line so it fits into closed tube.
7. Cap tube securely and label tube with patient's entire name and collection date and time.
8. Maintain swab container at 2 to 30° C (refrigerate temperature is preferred), transport within 60 days of collection.
Specimen Type: Vaginal
Supplies: Aptima Multitest Swab Collection Kit (T584)
Container/Tube: Aptima Multitest Swab
Specimen Volume: 1 Swab
Collection Instructions:
1. Specimens must be collected using the Aptima Multitest Swab Collection Kit.
2. Insert swab (pink shaft) about 5 cm past introitus and rotate gently for 30 seconds.
3. Place pink swab into Aptima transport tube provided in collection kit.
4. Snap off pink swab at score line so it fits into closed tube.
5. Cap tube securely and label tube with patient's entire name and collection date and time.
6. Maintain swab container at 2 to 30° C (refrigerate temperature is preferred), transport within 60 days of collection.
Specimen Type: Urethra (Male patients only)
Supplies: Aptima Unisex Swab Collection Kit (T583)
Container/Tube: Aptima Unisex Swab
Specimen Volume: 1 Swab
Collection Instructions:
1. Specimens must be collected using the Aptima Unisex Swab Collection Kit.
2. Patient should not have urinated for at least 1 hour prior to collection.
3. With a rotating movement, insert swab (blue shaft) 2 to 4 cm into urethra.
4. Once inserted, rotate swab gently at least 1 full rotation using sufficient pressure to ensure swab comes in contact with all urethral surfaces. Allow swab to remain inserted for 2 to 3 seconds.
5. Place blue swab in transport tube provided in collection kit.
6. Snap off blue swab at score line so it fits into closed tube.
7. Cap tube securely, and label tube with patient's entire name and collection date and time.
8. Maintain swab container at 2 to 30° C (refrigerate is preferred temperature) within 60 days of collection. If longer storage is needed, freeze at -20 to -70° C for an additional 90 days.
Specimen Type: Urine
Supplies: Aptima Urine Transport Tube (T582)
Container/Tube: Aptima urine specimen transport tube
Specimen Volume: 15 to 20 mL
Collection Instructions:
1. Patient should not have urinated for at least 1 hour prior to specimen collection.
2. Patient should collect first portion of random voided urine (first part of stream) into a sterile, plastic, preservative-free container.
3. Within 24 hours of collection, transfer 2 mL of urine into the Aptima urine specimen transport tube using the disposable pipette provided. The correct volume of urine has been added when the fluid level is between the black fill lines on the Aptima urine transport tube.
4. Maintain Aptima urine specimen transport tube at 2 to 30° C (refrigerate temperature is preferred), transport within 30 days of collection.
Specimen Type: Penile/meatal
Supplies: Aptima Multitest Swab Collection Kit (T584)
Container/Tube: Aptima Multitest Swab
Specimen Volume: 1 Swab
Collection Instructions:
1. Specimens must be collected using the Aptima Multitest Swab Collection Kit.
2. Roll the swab (pink shaft) just at the tip or outside the opening to the penis. Be sure to roll the swab completely around the opening to get the best sample.
3. Immediately place the pink swab into the collection tube.
4. Carefully break the pink swab shaft at the score line and recap the tube.
5. Cap tube securely and label tube with patient's entire name and collection date and time.
6. Maintain swab container at 2 to 30° C (refrigerate is preferred temperature) within 60 days of collection. If longer storage is needed, freeze at -20 to -70° C for an additional 90 days.
Specimen Stability
| Specimen Type | Temperature | Time | Special Container |
|---|---|---|---|
| varies | Refrigerated (preferred) | 30 days | APTIMA VIAL |
| Frozen | 60 days | APTIMA VIAL | |
| Ambient | 30 days | APTIMA VIAL |
Reference Range
Negative
CPT
87563
Day(s) Performed
Tuesday and Thursday
Report Available
24-72 hours
Reject Due To
Midstream urine specimen
Clean catch urine specimen
Over-filled or under-filled urine transport tubes
Specimen collected into a SurePath device
Transport tubes containing a cleaning swab or more than 1 swab
Multiple sources on single tube